The Insights tile appears on all of the Operate Detail pages displays alerts (insights) for each layer of hardware present in the hierarchy of your network Infrastructure including Network Details, Card Details, Node Details, OLT Details, Port Details and ONU Details.

The Insights tile contains an Insights column (second column from the right). Each insight that can be displayed in this column, along with the alert condition associated with that insight, are detailed below.

note

Some insights may not clear for devices that are removed between scans. These insights will be automatically deleted after 30 days if there is no reoccurence.

Capacity

Backplane

Insight NameDescriptionPlatform
Backplane Egress bandwidth crossed thresholdAlerts when an outbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
Backplane Ingress bandwidth crossed thresholdAlerts when an inbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access

Module

Insight NameDescriptionPlatform
Egress bandwidth crossed thresholdAlerts when an outbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
High CPU utilizationAlerts when a Switch Module(SM)'s CPU load is approaching and crosses a threshold where service could be impacted and migration to newer hardware is recommended. Total Access
Ingress bandwidth crossed thresholdAlerts when an inbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
Muxponder Egress bandwidth crossed thresholdAlerts when an outbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
Muxponder Ingress bandwidth crossed thresholdAlerts when an inbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
Uplink Egress bandwidth crossed thresholdAlerts when an outbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
SDX
Uplink Ingress bandwidth crossed thresholdAlerts when an inbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
SDX

PON

Insight NameDescriptionPlatform
PON Downstream bandwidth crossed thresholdAlerts when an inbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
SDX
3rd Party
PON Upstream bandwidth crossed thresholdAlerts when an outbound bandwidth utilization threshold has been exceeded. The severity of this insight will adjust based on thresholds crossed. Total Access
SDX
3rd Party

Equipment

Module

Insight NameDescriptionPlatform
Card restartedAlerts when an Optical Line Terminal (OLT) card restarted. Total Access
File system issuesAlerts when card is not running properly due to issues such as lost sectors, unacquired sectors or cross-linked files. Proactively identifying these issues can prevent loss of service to customers and emergency truck rolls for failed hardware. Total Access
SCM card restartedAlerts when the SCM card restarted. Total Access
Invalid SM MAC addressAlerts when an SM has been programmed with an invalid MAC address. Total Access

ONU

Insight NameDescriptionPlatform
3XX ONU unsupported on SDXAlerts when a 3xx-series ONU is connected to an SDX OLT, which is not supported. SDX
ONU OMCI lossAlerts when ONU is not properly communicating with the OLT. Total Access

SFP

Insight NameDescriptionPlatform
SFP unknownAlerts for an SFP from which data cannot be collected or data is invalid. Total Access
SDX

Status

Insight NameDescriptionPlatform
Port operationally unknownAlerts when an enabled port’s status cannot be detected is found. Total Access

Support Need

Insight NameDescriptionPlatform
Slot unknownAlerts when an Access Module in the chassis is not recognized by the system. Total Access

Intent Reality Mismatch

Connection Issue

Insight NameDescriptionPlatform
Node connection failure during scanAlerts when Mosaic Operate cannot connect to Node during scan. Total Access

Event Detection

Insight NameDescriptionPlatform
Auto upgrade failureAlerts when there is an auto upgrade failure caused by either a software version mismatch, TFTP error in processing, or module upgrade operation failure. Total Access
Backplane down card in system inventoryAlerts when status for backplane connection to the card is down for an occupied slot. Total Access
Backplane running errorsAlerts when an enabled backplane connection has L1-L3 errors present. e.g. CRC errors, frame errors, runts, giants, etc. Total Access
Backplane up card not in system inventoryAlerts when status for backplane connection shows a card is not properly communicating with the system. Total Access
Card communication failureAlerts when OLT card is unable to properly communicate with the chassis. Total Access
Card removedAlerts when OLT card has been removed from the chassis. Total Access
ERPS interface downAlerts when a link in the Ethernet Ring Protection Switching (ERPS) is physically down. Total Access
ERPS openAlerts when ERPS is open and no longer providing traffic resilience. Total Access
ERPS out-of-serviceAlerts when outdated ERPS provisioning is present. Total Access
Fallback timing source activeAlerts when the current timing source is neither primary nor secondary. Total Access
High downstream UBCsAlerts when a high amount of uncorrectable byte counts (UBCs) are observed on the downstream of a DSL line. Total Access
High rate asymmetryAlerts when the downstream to upstream ratio is highly asymmetric. This condition may limit the peak download rate due to TCP issues. Total Access
High upstream UBCsAlerts when a high amount of UBCs are observed on the upstream of a DSL line. Total Access
Incorrect backplane speedAlerts when the backplane speed between the Switch Module and Access Module is not operating at maximum speed. Total Access
IP-Host not runningAlerts when faults are detected that would prevent IP host from running. Total Access
Link down on a bonded DSL serviceAlerts when one or more links of a bonded DSL service is down. This will impact customer experience. Total Access
Module software version mismatchAlerts when the software version of an Access Module is not in sync with the configured System Release version. Total Access
OLT/ONU interop incompatibility issueAlerts when the certain ONU models are in use with the 1187502F1 OLT module. There is a known incompatibility issue that can cause Upstream BIP errors. The recommendation is to upgrade to a newer generation OLT. Total Access
ONU discoveringAlerts when an ONU provisioning exists and the ONU is actively attempting to become active. Total Access
SDX
ONU inactiveAlerts when an ONU provisioning exists but the ONU is not attempting to be discovered. Total Access
SDX
3rd Party
ONU shutdown-maintenanceAlerts when an ONU provisioning exists but is disabled for maintenance. Total Access
ONU video lossAlerts when video data stream is absent from an ONU. Total Access
Port duplexity issuesAlerts when an enabled port is operating at less than full duplex. Total Access
PWE downAlerts when a pseudowire is enabled but operationally down. Total Access
PWE unterminated circuitAlerts when an unterminated pseudowire circuit is detected Total Access
Redundancy downAlerts when there is a fault preventing redundancy between both Switch Modules which could result in service disruption. Total Access
SIP subscriber registration failureAlerts when configured voice subscriber fails to register with upstream registrar. Total Access
SDX
T1 downAlerts when a T1 is enabled but operationally down. Total Access
T1 in testAlerts when a T1 test is in progress on the interface. Total Access
T1 out-of-service maintenanceAlerts when a T1 is disabled for maintenance. Total Access

Exceed Range

Insight NameDescriptionPlatform
ONU high distanceAlerts when an ONU is deployed at a distance greater than what the standard specifies. Total Access
SDX

Provisioning Concern

Insight NameDescriptionPlatform
Battery monitoring enabled on non-voice ONUAlerts when battery monitoring is enabled for an ONU without voice support. This could lead to false battery alarms. Total Access
Current timing source not highest qualityAlerts when a node has a timing source with higher quality that is not currently in use. Total Access
Downstream FEC disabled on XGS-PONAlerts when Downstream FEC is disabled for an XGS-PON interface. Total Access
3rd Party
ERPS misconfigured VLANAlerts when the Ethernet Virtual Circuit (EVCs) are incorrectly provisioned and could unexpectedly cause service disruption. Total Access
ERPS not lowest hop-countA remote terminal (RT) in an ERPS is not referencing the timing source with the lowest number of devices between it and the timing source. Total Access
ERPS primary timing source not fixedAn RT's primary timing sources in an ERPS is improperly configured. Total Access
ERPS RT's revertive and hop-count not enabledAn RT in an ERPS is improperly configured to offer resilience. Total Access
ERPS secondary timing source not fixedAn RT's secondary timing source in an ERPS is improperly configured. Total Access
EVC disabledAlerts when an EVC is disabled/shutdown. Total Access
EVC genericAlerts for an EVC with outdated virtual connections. Total Access
EVC not runningAlerts when an EVC is enabled but unable to carry traffic due to a fault. Possibly due to conflict, improper provisioning, etc. Total Access
EVC-Map disabledAlerts when an EVC-Map is configured but disabled. Total Access
EVC-Map not runningAlerts when faults are detected that would prevent an EVC-Map from running. Total Access
IGMP EVC proxy conflictAlerts on improper configuration of Internet Group Management Protocol (IGMP). Total Access
Incorrect node clock timeAlerts when the clock time of the node is not set correctly. This can lead to inaccurate timestamps for Operate data. Total Access
MEVC disabledAlerts when an MEVC is disabled/shutdown. Total Access
MEVC genericAlerts for an MEVC with outdated virtual connections. Total Access
MEVC not runningAlerts when an MEVC is enabled but unable to carry traffic due to a fault. Possibly due to conflict, improper provisioning, etc. Total Access
ONU shutdownAlerts when an ONU provisioning exists but is disabled. Total Access
ONU upgrade failureAlerts when an ONU software upgrade has failed. Total Access
Port operationally downAlerts when an enabled port is down. Total Access
Primary timing source downAlerts when the primary source for system timing is down. Total Access
Primary timing source set to fixedAlerts when the primary timing source is erroneously provisioned with 'Fixed'. Total Access
PWE out-of-serviceAlerts when a pseudowire is provisioned and disabled. This state would result in no traffic on the specified link. The associated, outdated provisioning should be removed. Total Access
PWE out-of-service maintenanceAlerts when a pseudowire is disabled for maintenance. Total Access
Secondary timing source downAlerts when the secondary source for system timing is down. Total Access
Secondary timing source set to fixedAlerts when the secondary timing source is erroneously provisioned with 'Fixed'. Total Access
Timing both identicalAlerts when no redundancy is present for clock source. Both primary and secondary are configured to use the same source. Total Access
Time is not synchronized to a network time source.Alerts when the device time is not synchronized with a network time source. This could result in inaccurate alarm, log and performance data timestamps. Total Access
SDX
Timing both localBoth the primary and secondary timing sources are set to the local clock and not receiving timing from a proper source. Total Access
VCL no connectionAlerts when remnant provisioning is present for VCL connections. Out-dated provisioning can lead to confusion and in certain circumstances could be service impacting. Total Access

Network Data Collection Issue

Inventory Data

Insight NameDescriptionPlatform
Network inventory data missingAlerts when Mosaic Operate has not received SDX inventory data in 3 days. SDX

Network Data

Insight NameDescriptionPlatform
Network performance data missingAlerts when Mosaic Operate has not received SDX performance data in 12 hours. SDX

Performance & Stability

Event Detection

Insight NameDescriptionPlatform
Chronic ONU LOSAlerts when multiple ONU LOS active/clear events are detected for an ONU with 1 minute. Total Access
SDX
Extended ONU LOSAlerts when an ONU was lost for more than 5 minutes which may indicate an outage. Total Access
SDX
Multiple Link Down within one second in last 24 hoursAlerts when a bouncing link event is detected on an SM faceplate port. Total Access
Multiple ONU LOS in last 24hrsAlerts when an ONU receives multiple ONU LOS events in the last 24 hours. Total Access
SDX
ONU battery errorAlerts when an ONU does not have battery backup. This condition potentially results in service disruption due to minor power fluctuations. Total Access
ONU Fluctuating Upstream Optical Signal LossAlerts when an ONU has experienced significant variations in its upstream optical loss over the last 30 days. Total Access
SDX
3rd Party
ONU high downstream BIPAlerts when an ONU is experiencing large amounts of downstream BIPs, and the receive power is not within the standard range. High BIPs can potentially be service affecting. Total Access
SDX
3rd Party
ONU high upstream BIPAlerts when an ONU is experiencing large amounts of upstream BIPs, and the receive power is not within the standard range. High BIPs can potentially be service affecting. Total Access
SDX
3rd Party
PON degrade failureAlerts when a PON Degrade Fail alarm has been detected. Any of the following conditions could generate this alarm:
  • Ethermac FCS error
  • Ethermac Buffer Overflow error
  • GEM Defrag FCS Error Case
  • OMCI CRC Error Case
  • OMCI drop due to large packet size
  • PLOAM resync-counter monitoring
  • PON ID Corruption monitoring
  • Complete Defrag Drop Case
Total Access
PON hardware failureAlerts when a PON HW Fail alarm has been detected. Any of the following conditions could generate this alarm:
  • DDR Failure
  • HBM Failure
Total Access
Port running errorsAlerts when an enabled port has L1-L3 errors. e.g. CRC errors, frame errors, runts, giants, etc. Total Access
Prolonged Unused ONU ProvisioningAlerts when an ONU has not been operationally 'up' in the last 30 days. Total Access
SDX
3rd Party
PWE card errorsAlerts when a pseudowire is experiencing errors that would degrade customer traffic. Potential causes include timing issues, VLAN priority, latency, etc. Total Access
PWE ONU errorsThe Operate system conducts the same alerting procedures for an ONU or a PWE connection, including PWE card↔️PWE card or PWE card↔️PWE ONU; however, the scope of these alerts is expanded further with coverage to FTTP and in PWE. Total Access
Possible disturbed PONAlerts when PON receives signals that deviate from standard parameters, indicating potential traffic disruptions and performance issues. Total Access
SDX
3rd Party
T1 errorsAlerts when a T1 with physical layer errors are present. Total Access

Physical Plant

Connection Issue

Insight NameDescriptionPlatform
High RX powerAlerts when an SFP is approaching or exceeds receive light level upper-limit threshold. Total Access
SDX
Low RX powerAlerts when an SFP is approaching or exceeds receive light level lower-limit threshold. Total Access
SDX
No RX powerAlerts when an SFP is not receiving any light. Total Access
SDX
OLT high RX powerAlerts when an OLT has a receive power higher than what the standard allows. Total Access
SDX
3rd Party
OLT high TX powerAlerts when the transmit power at the OLT is higher than what the standard allows. Total Access
SDX
3rd Party
OLT low RX powerAlerts when the receive power at the OLT is lower than what the standard allows. Total Access
SDX
3rd Party
OLT low TX powerAlerts when the transmit power at the OLT is lower that than what the standard allows. When this insight is active, it will give various SFP details on why it is active. Total Access
SDX
3rd Party
ONU High OLT RX Optical Power AnomalyAlerts when a reported OLT RX power level from an ONU is higher than average reported OLT RX power level across a PON. Total Access
SDX
3rd Party
ONU high RX powerAlerts when an ONU has a receive power higher than what the standard allows. Total Access
SDX
3rd Party
ONU high TX powerAlerts when an ONU has a transmit power greater than what the standard specifies. Total Access
SDX
3rd Party
ONU low RX powerAlerts when an ONU has a receive power lower than what the standard allows. Total Access
SDX
3rd Party
ONU low TX powerAlerts when an ONU has a transmit power that is lower than what the standard specifies. Total Access
SD
3rd PartyX
ONU unexpected signal lossAlerts when the actual signal loss between the OLT and ONU is significantly different than the theoretical loss given known transmit and receive powers, split ratios, and distance. Total Access
SDX
3rd Party
Possible past power outageAlerts when an ONU has had multiple loss of power events in the last 24 hours. Total Access
SDX

Copper

Insight NameDescriptionPlatform
Bad spliceAlerts when a signature is detected that infers improper wiring, splicing, or physical state of a DSL line. This state could be caused by a class of physical issues including poor physical contact of a splice, corrosion, moisture, etc. Total Access
Long line lengthAlerts when the estimated cable run from a specified DSL port is greater than what the standard allows. Total Access

Fiber

Insight NameDescriptionPlatform
Fiber bendAlerts when a fiber bend signature has been detected that will impact performance for an ONU. Total Access
SDX
3rd Party